J3 connector is to close to the hole MH1 ??
+
J3 connector is to close to the hole MH1 ??
J15 must be right angle or vert ??
+
J15 must be right angle or vert ??
J4  is unmounted – to be checked the DigiKey stock (ED90342TR-ND)
+
J4  is unmounted – to be checked the DigiKey stock (ED90342TR-ND)
The silk for S/N on the board must be fill with white color
+
The silk for S/N on the board must be fill with white color
The C22 shape clearance is very close
+
The C22 shape clearance is very close
If the RTC feature is not implemented in the actual V7.0 version then the Y1 crystal may be missing – to be tested
+
If the RTC feature is not implemented in the actual V7.0 version then the Y1 crystal may be missing – to be tested
In the fabricartion notice must be added thermal specifications for the Microphone
+
In the fabricartion notice must be added thermal specifications for the Microphone
In the fabricartion notice must be added thermal specifications for the plastic connectors
+
In the fabricartion notice must be added thermal specifications for the plastic connectors

Revision as of 11:57, 7 November 2012

Summary

Hardware test reports and suggestions for Idrive X1 Main Board v7.


Tests

Hardware tests:


Power Supply Tests

Firmware Changes

The FREX pin should not be initialization as output in the camera driver because is connected to GND or to establish if is necessary to place resistors ??


Recommendations

J3 connector is to close to the hole MH1 ?? J15 must be right angle or vert ?? J4 is unmounted – to be checked the DigiKey stock (ED90342TR-ND) The silk for S/N on the board must be fill with white color The C22 shape clearance is very close If the RTC feature is not implemented in the actual V7.0 version then the Y1 crystal may be missing – to be tested In the fabricartion notice must be added thermal specifications for the Microphone In the fabricartion notice must be added thermal specifications for the plastic connectors